ACX-140 AC Current and Voltage Two Wire Transmitter
AC Current (5A) and Voltage (250VAC)
Input
12-42 VDC 2 Wire Output Loop Powered
Ruggedized Hockey Puck Style Housing
Isolated Input/Output/Case
Click Here to view 100 Series Data Sheet
Click here for printer friendly version
Click here for Instruction Manual
|
|

ACX-141 AC Current and Voltage Two
Wire Transmitter
AC Current (5A) and Voltage (250VAC) Input
12-42 VDC 2 Wire Output Loop Powered
Ruggedized Hockey Puck Style Housing
Isolated Input/Output/Case
Up to 100% Zero Suppression
Click Here to view 100 Series Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|

FDX-150 Frequency Two Wire Transmitter
Frequency Inputs up to 30KHz.
12-42 VDC 2 Wire Output Loop Powered
Ruggedized Hockey Puck Style Housing
Isolated Input-Output-Case
Click Here to view 100 Series Data Sheet
Click here for printer friendly version
Click here for Instruction Manual
|
|

MVX-106 Millivolt Two Wire
Transmitter
mVDC Input Spans from 0.5 to 100 mVDC
12-42 VDC 2 Wire Output Loop Powered
Ruggedized Hockey Puck Style Housing
Click Here to view 100 Series Data Sheet
Click here for printer friendly version
Click here for Instruction Manual
|

MVX-126 Isolated Millivolt Two Wire Transmitter
mVDC Input Spans from 0.5 to 100 mVDC
12-42 VDC 2 Wire Output Loop Powered
Ruggedized Hockey Puck Style Housing
Isolated Input-Output-Case
Click Here to view 100 Series Data Sheet
Click here for printer friendly version
Click here for Instruction Manual
|
|
PTX-173 Potentiometer Two Wire Transmitter
Potentiometer Input with spans from 50 Ohms to 100kOhms
12-42 VDC 2 Wire Output Loop Powered
Ruggedized Hockey Puck Style Housing
Click Here to view 100 Series Data Sheet
Click here for printer friendly version
Click here for Instruction Manual
|

RBX-172 RTD Two Wire Transmitter
RTD and Ohm inputs with spans from 1 to 400 ohms
12-42 VDC 2 Wire Output Loop Powered
Ruggedized Hockey Puck Style Housing
Isolated Input-Output-Case
Click here to view 100 Series Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|
|

RBX-174 RTD Two Wire Transmitter
RTD and Ohm inputs with spans from 1 to 400 ohms
12-42 VDC 2 Wire Output Loop Powered
Ruggedized Hockey Puck Style Housing
Click here to view 100 Series Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|

TCX-126 Thermocouple Two Wire Transmitter
J, K, T, E, R, S and B Thermocouple Inputs
-20 to 100 mVDC Input Ranges
12-42 VDC 2 Wire Output Loop Powered
Ruggedized Hockey Puck Style Housing
Click here to view 100 Series Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|
|
|
200 Series
|

ACX-240 AC Current and Voltage Two Wire Transmitter
AC Current (5A) and Voltage (250VAC) Input
12-42 VDC 2 Wire Output Loop Powered
Compact 25mm (1 Inch) Wide DIN Housing
Isolated Input-Output
Click here to view 200 Series Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|
|

FDX-250 Frequency Two Wire Transmitter
Frequency Inputs up to 30KHz.
12-42 VDC 2 Wire Output Loop Powered
Compact 25mm (1 Inch) Wide DIN Housing
Isolated Input-Output
Click here to view 200 Series Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|

MPF-250 Frequency Two Wire Transmitter
Frequency Inputs from 0.031Hz to 12.5KHz.
Microprocessor based one touch calibration
12-42 VDC 2 Wire Output Loop Powered
Compact 25mm (1 Inch) Wide DIN Housing
Isolated Input-Output
Click here to view MPF-250 Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|
|

MVX-206 Millivolt Two Wire Transmitter
mVDC Input Spans from 0.5 to 100 mVDC
12-42 VDC 2 Wire Output Loop Powered
Compact 25mm (1 Inch) Wide DIN Housing
Click here to view 200 Series Data Sheet
Click here for printer-friendly verison
Click here for Instruction Manual
|

MVX-226 Isolated Millivolt Two Wire Transmitter
mVDC Input Spans from 0.5 to 100 mVDC
12-42 VDC 2 Wire Output Loop Powered
Compact 25mm (1 Inch) Wide DIN Housing
Isolated Input-Output
Click here to view 200 Series Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|
|

PTX-273 Potentiometer Two Wire Transmitter
Potentiometer Input with spans from 50 Ohms to 100kOhms
12-42 VDC 2 Wire Output Loop Powered
Compact 25mm (1 Inch) Wide DIN Housing
Click here to view 200 Series Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|

RBX-272 RTD Two Wire Transmitter
RTD and Ohm inputs with spans from 1 to 400 ohms
12-42 VDC 2 Wire Output Loop Powered
Compact 25mm (1 Inch) Wide DIN Housing
Isolated Input-Output
Click here to view 200 Series Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|
|
RBX-274 Isolated RTD Two Wire Transmitter
RTD and Ohm inputs with spans from 1 to 400 ohms
12-42 VDC 2 Wire Output Loop Powered
Compact 25mm (1 Inch) Wide DIN Housing
Click here to view 200 Series Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|

SCX-202 Isolated Two-Wire Signal Converter
2-Wire output Loop Power Signal Conditioner
Accepts mADC or VDC inputs
4-20 mADC 2 Wire Output
Compact 22.5mm DIN Case
Click here to view 200 Series Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|
|

TCX-226 Isolated Thermocouple Two Wire Transmitter
J,K, T, E, R, S and B Thermocouple Inputs
-20 to 100 mVDC Input Ranges
12-42 VDC 2 Wire Output Loop Powered
Compact 25mm ( 1 inch) Wide DIN Housing
Isolated Input-Output
Click here to view TCX-226 Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|

TCX-227 Isolated Thermocouple 2-Wire Transmitter
J,K,T,E,N,B,R,S,G,C,D Thermocouple Inputs
SMART TOUCH One Button calibration
12-42 VDC 2 Wire Output Loop Powered
Compact 25mm (1 inch) Wide DIN Housing
Isolated Input-Output
Click here to view TCX-227 Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|
|
|
300 Series
|

ACT-340 AC Current and Voltage Three Wire Transmitter
AC Current (5A) and Voltage (250VAC) Input
Voltage and Current Outputs
15-42 VDC 3 Wire Output Loop Powered
Compact 25mm (1 Inch) Wide DIN Housing
Isolated Input-Output
Click here to view ACT-340 Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|
|

FDT-350 Frequency Three Wire Transmitter
Frequency Inputs up to 30KHz.
Voltage and Current Outputs
15-42 VDC 3 Wire Output Loop Powered
Compact 25mm (1 Inch) Wide DIN Housing
Isolated Input-Output
Click here to view FDT-350 Data Sheet
Click here get printer-friendly version
Click here for Instruction Manual
|

MPF-350 Frequency Three Wire Transmitter
Frequency Inputs from 0.031Hz to 38KHz.
Microprocessor based one touch calibration
Voltage and Current Outputs
15-42 VDC 3 Wire Output Loop Powered
Compact 25mm (1 Inch) Wide DIN Housing
Isolated Input-Output
Click here to view MPF-350 Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|
|

MVT-306 non-Isolated Millivolt Three Wire Transmitter
mVDC Input Spans from 0.5 to 100 mVDC
Voltage and Current Outputs
15-42 VDC 3 Wire Output Loop Powered
Compact 25mm (1 Inch) Wide DIN Housing
Click here to view 300 Series Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|

MVT-326 Isolated Millivolt Three Wire Transmitter
mVDC Input Spans from 0.5 to 100 mVDC
Voltage and Current Outputs
15-42 VDC 3 Wire Output Loop Powered
Compact 25mm (1 Inch) Wide DIN Housing
Isolated Input-Output
Click here to view 300 Series Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|
|

PTT-373 Non-Isolated Potentiometer Three Wire Transmitter
Potentiometer Input with spans from 50 Ohms to 100kOhms
Voltage and Current Outputs
15-42 VDC 3 Wire Output Loop Powered
Compact 25mm (1 Inch) Wide DIN Housing
Click here to view 300 Series Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|

PTT-374 Isolated Potentiometer Three Wire Transmitter
Potentiometer Input with spans from 50 Ohms to 100kOhms
Voltage and Current Outputs
15-42 VDC 3 Wire Output Loop Powered
Compact 25mm (1 Inch) Wide DIN Housing
Isolated Input – Output
Click here to view 300 Series Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|
|

RBT-372 Isolated RTD/Ohms Three Wire Transmitter
RTD and Ohm inputs with spans from 1 to 400 ohms
Voltage and Current Outputs
15-42 VDC 3 Wire Output Loop Powered
Compact 25mm (1 Inch) Wide DIN Housing
Isolated Input-Output
Click here to view 300 Series Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|

RBT-374 Non-Isolated RTD/Ohms Three Wire Transmitter
RTD and Ohm inputs with spans from 1 to 400 ohms
Voltage and Current Outputs
15-42 VDC 3 Wire Output Loop Powered
Compact 25mm (1 Inch) Wide DIN Housing
Click here to view 300 Series Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|
|
|

SCT-302 Signal Converter
Input of mADC and VDC Signals
Voltage and Current Outputs
15-42 VDC 3 Wire Output Loop Powered
Compact 25mm (1 Inch) Wide DIN Housing
Isolated Input-Output
Click here to view 300 Series Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|
|
|

TCT-327 Isolated Thermocouple Three Wire Transmitter
J,K,T,E,N,B,R,S,G,C,D Thermocouple Inputs
SMART TOUCH One Button calibration
Voltage and Current Outputs
15-42 VDC 3 Wire Output Loop Powered
Compact 25mm (1 Inch) Wide DIN Housing
Isolated Input-Output
Click here to view TCT-327 Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|
300L Series
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|

SCT-302L Signal Converter
Input of mADC and VDC Signals
Outputs of 1-5 or 0-5 VDC
7-42 VDC 3 Wire Output Loop Powered, Low 5 mA Max current draw
Compact 25mm (1 Inch) Wide DIN Housing
Isolated Input-Output
Click here to view 300L Series Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|
|
|
|
|
Four Wire Series
|
|
|
|
|
|
|
|
MVT-06 Non-Isolated mVDC Transmitter
mVDC Input Spans from 0.5 to 100 mVDC
Voltage and Current Outputs
117 VAC Power Standard, optional 230 VAC and 24 VDC Power available
Study Rack Mount Metal Case
Click here to view Data Sheet for MVT-06
Click here for printer friendly version
Click here for Instruction Manual
|
MVT-26 Isolated mVDC Transmitter
mVDC Input Spans from 0.5 to 100 mVDC
Voltage and Current Outputs
117 VAC Power Standard, optional 230 VAC and 24 VDC Power available
Study Rack Mount Metal Case
Isolated Input-Output-Case
Click here to view MVT-26 Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|
|

PDR-82 Pulse Duration Receiver
Input Pulse from the PDT-80
Voltage or Current Output
117 VAC Power Standard, optional 230 VAC and 24 VDC Power available
Study Rack Mount Metal Case
Click here to view PDR-82 Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|

PDT-80 Pulse Duration Transmitter
Voltage or Current input
15 Second pulse Duration Output
117 VAC Power Standard, optional 230 VAC and 24 VDC Power available
Study Rack Mount Metal Case
Click here to view PDT-80 Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|
|

PTT-73 Potentiometer Transmitter
Potentiometer Input with spans from 50 Ohms to 100k Ohms
Voltage and Current Outputs
117 VAC Power Standard, optional 230 VAC and 24 VDC Power available
Study Rack Mount Metal Case
Isolated Input-Output-Case
Click here to view PTT-73 Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|

RBT-72 Isolated RTD Transmitter
RTD and Ohm inputs with spans from 1 to 400 ohms
Voltage and Current Outputs
117 VAC Power Standard, optional 230 VAC and 24 VDC Power available
Study Rack Mount Metal Case
Isolated Input-Output-Case
Click here to view Data Sheet for RBT-72
Click here for printer-friendly version
Click here for Instruction Manual
|
|

RBT-74 non-Isolated RTD Transmitter
RTD and Ohm inputs with spans from 1 to 400 ohms
Voltage and Current Outputs
117 VAC Power Standard, optional 230 VAC and 24 VDC Power available
Study Rack Mount Metal Case
Click here to view Data Sheet for RBT-74
Click here for printer-friendly version
Click here for Instruction Manual
|

SCT-02 Signal Conditioner
mADC and VDC inputs
Voltage and Current Outputs
117 VAC Power Standard, optional 230 VAC and 24 VDC Power available
Study Rack Mount Metal Case
Isolated Input-Output-Case
Click here for SCT-02 Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|
|

SCT-02/O66 Dual Output Signal Conditioner
Single mADC and VDC inputs
Dual 4-20 mADC Current Outputs
117 VAC Power Standard, optional 230 VAC and 24 VDC Power available
Study Rack Mount Metal Case
Isolated Input-Output-Case
Click here for SCT-02/O66 Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|

SGT-90 Strain Gauge Transmitter
Strain Gauge Input
Voltage and Current Outputs
117 VAC Power Standard, optional 230 VAC and 24 VDC Power available
Study Rack Mount Metal Case
Isolated Input-Output-Case
Click here to view SGT-90 Data Sheet
Click here for printer-friendly version
Click here for Instruction Manual
|
|

TCT-26 Thermocouple Transmitter
J, K, T, E, R, S and B Thermocouple Inputs
-20 to 100 mVDC Input Ranges
Voltage and Current Outputs
117 VAC Power Standard, optional 230 VAC and 24 VDC Power available
Study Rack Mount Metal Case
Isolated Input-Output-Case
Click here to view Data Sheet for TCT-26
Click here for printer-friendly version
Click here for Instruction Manual
|
Other Models
|

IPS 2400-5 Universal Input AC to DC or DC to DC 5 VDC Power Supply
Provides +5 VDC @ 1 Amp
Input Voltage of 85 to 132 VAC or 100 to 150 VDC
Compact 22.5mm DIN Case
Isolated Power Output
Click here for IPS 2400-5 Data Sheet
Click here for printer-friendly version
|
|

IPS 2400-12 Universal Input AC / DC to DC 12 VDC Power Supply
Provides +12 VDC @ 400 mAmp
Input Voltage of 85 to 132 VAC or 100 to 150 VDC
Compact 22.5mm DIN Case
Isolated Power Output
Click here for IPS 2400-12 Data Sheet
Click here for printer-friendly version
|

IPS 2400-24 Universal Input AC / DC to DC 24 VDC Power Supply
Provides +24 VDC @ 200 mAmp
Powers up to 10 2 wire transmitters
Input Voltage of 85 to 132 VAC or 100 to 150 VDC
Compact 22.5mm DIN Case
Isolated Power Output
Click here for IPS 2400-12 Data Sheet
Click here for printer-friendly version
|
|
IPS 2402 Instrument Power Supply AC to DC
Provides +26VDC @ 50 mAmp
Powers up to two 2-Wire loops
Input Voltage of 117 or 230 VAC
Compact 22.5mm DIN Case
Isolated Power Output
Click here for IPS 2402 Data Sheet
Click here for printer-friendly version
|

IPS 2416 Universal Input AC to DC or DC to DC Power Supply
Provides +24 VDC @ 320 mAmp
Powers up to 16 2 Wire loops
Input Voltage of 105 to 250 VAC or 100-350 VDC
Compact 22.5mm DIN Case
Isolated Power Output
Click here for IPS 2416 Data Sheet
Click here for printer-friendly version
|
|
SCT-502 Isolated Signal Converter AC Powered
Signal Isolator, 117 VAC powered
Input to Output to Power Isolation
Unipolar VDC or mADC inputs
Unipolar mADC or VDC Outputs
Compact 45mm Wide DIN Case
Click here for SCT-502 Data Sheet
Click here for printer-friendly environment
Click here for Instruction Manual
|

SCT 502-1 Isolated Bipolar Signal Converter AC Powered
Signal Isolator, 117 VAC powered
Input to Output to Power Isolation
Bipolar VDC or 4-20 mADC inputs
Bipolar VDC Outputs
Compact 45mm Wide DIN Case
Click here for SCT 502-1 Data Sheet
Click here for printer-friendly version
|
|
|